Fix it
Low battery won't clear
Panel still says low battery. Tired battery or a charging fault?
Quick fix
- Mains on? If MAINS is also showing, fix that first. No mains, no charging.
- Check the battery's date. Older than about 3 years or unknown? Replace it.
- Meter the charge voltage on the battery leads with the battery off. Should be about 13.7–13.8 V.
- Check the leads. Loose spades, corrosion, reversed polarity, blown battery fuse.
- New battery fitted? Give it time to charge. The fault clears when the next load test passes.
Draft. Not yet checked on site. Confirm against the manual. Report an error
Why a good-looking battery fails
Panels test the battery under load, not just its resting voltage. A tired battery can read fine on your meter and still fail the panel's test.
| Panel | Battery test | Charge |
|---|---|---|
| Ness D8x / D16x | Every hour and on code entry | 13.8 V, limited to 350 mA |
| Paradox EVO | Every 60 seconds. Trouble at 10.5 V with no AC | 350 or 850 mA (selectable) |
| Inner Range Inception | Low battery at 11.0 V. Cuts out at 10.4 V to protect it | 13.75 V, up to 500 mA. 7 Ah ≈ 18 h to recharge |
| Risco LightSYS Plus | Allow 24 h+ to charge | Replace every 3–5 years |
Reversed leads on a Paradox blow the battery fuse. On a Ness, the current-limit globes glowing bright means a dud battery or reversed leads.
Is the battery big enough now?
Sites grow. Extra detectors and modules can outgrow a 7 Ah battery. Run it through the battery calculator.