  1. Programming is from an LCD terminal or the Insight software.
  2. LAN termination: on Concept, the LAN is terminated on two modules only (unless you use isolators).
  3. Module LEDs both on = not addressed. Check 0V, A and B.
  4. Module LED flashing with the other on = duplicate module number.
  5. Upgrading to Integriti? Remove the termination links from the Concept modules you keep.

Draft. Not yet checked on site. Confirm against the manual. Report an error

Module addressing

DIP switches 1–7 set the module number (binary value + 1). Switch 8 off.

Status

Concept is a legacy platform. Many sites are being moved to Integriti, which can reuse a lot of Concept LAN modules. Check compatibility with Inner Range before quoting a migration.

This guide's thinner than the others because Inner Range's Concept manuals weren't reachable. If you've got good Concept tips, send them in.