Interlogix · Alarm panel
Interlogix NetworX NX-4 / 6 / 8 / 8E
Defaulting and the enrol trick that fixes most module faults.
Quick fix
- Added, removed or swapped a keypad or module? Enter then exit program mode. The panel enrols everything (about 12 seconds).
- Service LED on after that = an enrolled module isn't talking. Check its wiring and address.
- Factory default: from program mode, enter the default sequence ending in
#. Three beeps, about 6 seconds. - During enrolment codes aren't accepted and a siren may chirp for a second. That's normal.
Draft. Not yet checked on site. Confirm against the manual. Report an error
Notes
- NX panels are discontinued. Parts still turn up, but quote a replacement if the board's failing.
- Hills Reliance XR can use some NX bus devices, with limited function.