Home › Risco › Risco LightSYS Plus
Risco · Alarm panel

Risco LightSYS Plus

Resets, bus tests, EOL options and wireless jamming.

Quick fix

  1. Locked out / factory reset: use the HandyApp to scan the panel ID. It gives a one-off reset key. Enter it within 5 minutes of the panel reset.
  2. Bus problems: run the bus test. 97% or lower = check wiring and DIP switches.
  3. Still dropping: fit 2k2 resistors across the data terminals at each end of the bus.
  4. Wireless jamming events: recalibrate, adjust the threshold or move the panel.
  5. Leaving programming: close the lid first or you'll get a front tamper.

Draft. Not yet checked on site. Confirm against the manual. Report an error

Before swapping the main board

Get into installer programming first, or the bus sirens will go off.

Wireless test

Results range from 11 to 86. A device's signal has to be above the background noise.

Specs at a glance
Power
14.4 V adaptor, permanently wired. Mains fuse 3.15 A
Battery
12 V up to 21 Ah. Charge 24 h+. Replace every 3–5 years
Current
500 mA per bus, 1 A AUX, 2 A total
Bus
Up to 3 lines. Red +12, black 0V, yellow/green data. 300 m per leg
EOL
2k2. DEOL 2k2/2k2. TEOL 4k7/6k8/12k
Cloud
Risco Cloud on by default