Ness D8x / D16x

Program mode, clearing, EOL, battery and siren limits.

Quick fix

  1. Into program mode: disarmed, master code then installer code. First power-up with the PROG/TAMP link off goes straight in.
  2. Out: P then E. All inputs are disabled while you're in.
  3. Clear user codes only: P98E (keeps the installer code).
  4. EOL: 2k2 default. Change at P129E. Turn EOL off per zone at P125E.
  5. Siren time: P29E, default 5 minutes.

Draft. Not yet checked on site. Confirm against the manual. Report an error

Check which board it is. Plain D8x, Deluxe (D8xD) and cellular (D8xCEL) each have their own manual.

Keypad icons

Shows Means
MAINS Mains off
LOW BATTERY Backup battery low
TAMPER, double flash Internal tamper
TAMPER, steady flash External tamper
LINE Phone line fault or failed to report
CELL low / 00 / noCELL 4G antenna, signal or SIM (CEL boards)

Heartbeat LED not flashing steadily

The manual's recovery (p. 6) clears programming from program mode, then has you disconnect one battery lead briefly and reconnect it.

Specs at a glance
Keypads
Up to 3, 100 m total. Bus +12V, CLK, DAT, COM
Battery
12 V 7 Ah. Charges at 13.8 V, 350 mA max
Plug pack
17 VAC, 1.4 A min
12 V detectors
500 mA total
SIREN / RESET
2 A continuous. Strobe 200 mA